HEATING, VENTALATION and AIR CONDITIONING TERMS

HVAC (heating, ventilation, and air conditioning) is a major subdiscipline of mechanical engineering. The goal of HVAC design is to balance indoor environmental comfort with other factors such as installation cost, ease of maintenance, and  energy efficiency. The discipline of HVAC includes a large number of specialized terms, many of which are summarized in this glossary.

 

Air changes per hour: The number of times per hour that the volume of a specific room or building is supplied or removed from that space by mechanical and natural ventilation.

 

Air conditioner: An appliance, system, or mechanism designed to dehumidify and extract heat from an area. Usually this term is reserved for smaller self contained units such as a residential system.

 

Air handler: A central unit consisting of a blower, heating and cooling elements, filter racks or chamber, dampers, humidifier, and other central equipment in direct contact with the airflow. This does not include the ductwork through the building.

 

British thermal unit (BTU): One BTU is the energy required to raise one pound of water one degree Fahrenheit. In the United States the power of HVAC systems (the rate of cooling and dehumidifying or heating) is sometimes expressed in BTU/hour instead of watts. Abbreviated BTU or Btu.

 

Chiller: A device that removes heat from a liquid via a vapor compression or absorption refrigeration cycle. This cooled liquid flows through pipes in a building and passes through coils in air handlers, fan-coil units, or other systems, cooling and usually dehumidifying the air in the building. Chillers are of two types; air cooled or water cooled. Air cooled chillers are usually outside and consist of condenser coils cooled by fan driven air. Water cooled chillers are usually inside a building, and heat from these chillers is carried by recirculating water to a heat sink such as an outdoor cooling tower.

 

Coil: Equipment that performs heat transfer to air when mounted inside an air handling unit or ductwork. It is heated or cooled by electrical means or by circulating liquid or steam within it.

 

Condenser:  A component in the basic refrigeration cycle that ejects or removes heat from the system. The condenser is the hot side of an air conditioner or heat pump. Condensers are heat exchangers, and can transfer heat to air or to an intermediate fluid.

 

Constant air volume: A system designed to provide a constant air flow. This term is applied to HVAC systems that have variable supply-air temperature but constant air flow rates. Most residential forced-air systems are small CAV systems with on/off control.

 

Controller (control theory): A device that controls the operation of part or all of a system. It may simply turn a device on and off, or it may more subtly modulate the set point of components. Most controllers are automatic but have user input such as temperature set points, e.g. a thermostat. Controls may be analog or digital.

 

Damper: A plate or gate placed in a duct to control air flow by increasing friction in the duct.

 

Duct: Specialized housing for the air flow.

 

Evaporator: A component in the basic refrigeration cycle that absorbs or adds heat to the system. Evaporators can be used to absorb heat from air or from a liquid. The evaporator is the cold side of an air conditioner or heat pump.

 

Fan coil unit: A small terminal unit that is often composed of only a blower and a heating and/or cooling coil, as is often used in hotels, condominiums, or apartments.

 

Fresh air intake: An opening through which outside air is drawn into the building. This may be to replace air in the building that has been exhausted by the ventilation system, or to provide fresh air for combustion of fuel.

 

Furnace: A component of an HVAC system that adds heat to air or an intermediate fluid by burning fuel (natural gas, oil, propane, butane, or other flammable substances) in a heat exchanger.

 

Grille: A facing across a duct opening, often rectangular in shape, containing multiple parallel slots through which air may be delivered or withdrawn from a ventilated space. The grille directs the air flow in a particular direction and prevents the passage of large items.

 

Heat gain, heat load, and heat loss: Terms for the amount of cooling (heat gain) or heating (heat loss) needed to maintain desired temperatures and humidities in controlled air. Regardless of how well-insulated and sealed a building is, buildings gain heat from sunlight, conduction through the walls, and internal heat sources such as people and electrical equipment. Buildings lose heat through conduction during cold weather. Engineers use a heat load calculations to determine the HVAC needs of the space being cooled or heated.

 

Intermediate fluid: A liquid or gas used to transfer heat between two heat exchangers. An intermediate fluid is used when the hot and cold fluids are too bulky (such as air) or difficult to handle (such as halocarbon refrigerant) to directly transfer the heat.

 

Louver: 1. Components made of multiple smaller blades, sometimes adjustable, placed in ducts or duct entries to control the volume of air flow. When used inside of ducts, their function is similar to that of a damper, but they can be manufactured to fit larger openings than a single-piece damper. 2. Blades in a rectangular frame placed in doors or walls to permit the movement of air.

 

Makeup air unit: An air handler that conditions 100% outside air. Typically used in industrial or commercial settings, or in "once-through" (blower sections that only blow air one-way into the building), "low flow" (air handling systems that blow air at a low flow rate), or "primary-secondary" (air handling systems that have an air handler or rooftop unit connected to an add-on makeup unit or hood) commercial HVAC systems.

 

Minimum outside air: The lowest amount of fresh air flow that can be allowed into a recirculating system. This limit is sent to ensure that the interior air remains safe and comfortable to breathe.

 

Outside air damper: An automatic louver or damper that controls the fresh air flow into an air handler and modulates to the most energy efficient setting.

 

Packaged terminal air conditioner: An air conditioner and heater combined into a single, electrically powered unit, typically installed through a wall and often found in hotels.

 

Packaged unit: An air-handling unit, defined as either "recirculating" or "once-through" design, made specifically for outdoor installation. They most often include, internally, their own heating and cooling devices. Very common in some regions, particularly in single story commercial buildings.

 

Plenum space: An enclosed space inside a building or other structure, used for airflow. Often refers to the space between a dropped ceiling and the structural ceiling, or a raised floor and the hard floor. Distinct from ductwork as a plenum is part of the structure itself. Cable and piping within a plenum must be properly rated for its fire and smoke indices.

 

Psychrometrics: The study of the behavior of air-water vapor mixtures. Water vapor plays an important role in energy transfer and human comfort in HVAC design.

 

Smoke damper: A damper or adjustable louver designed to augment the ventilation of a space during a fire.

 

System: General term used to refer to the set or a subset of components that perform a specific HVAC function within a building.

 

Terminal unit: A small component that contains a heating coil, cooling coil, automatic damper, or some combination of the three. Used to control the temperature of a single room.

 

Thermal zone: An individual space or group of neighboring indoor spaces that the HVAC designer expects will have similar thermal loads. Building codes may require zoning to save energy in commercial buildings. Zones are defined in the building to reduce the number of HVAC subsystems, and thus initial cost. For example, for perimeter offices, rather than one zone for each office, all offices facing west can be combined into one zone. Small residences typically have only one conditioned thermal zone, plus unconditioned spaces such as garages, attics, and crawlspaces, and basements.

 

Underfloor air distribution: A method for providing ventilation and space conditioning by using the air plenum below a raised floor to distribute conditioned air through diffusers directly to the occupied zone. <br>Variable air volume: An HVAC system that has a stable supply-air temperature, and varies the air flow rate to meet the temperature requirements. Compared to constant air volume systems, these systems conserve energy through lower fan speeds during times of lower temperature control demand.–

 

Source: Modern Refrigeration and Air Conditioning (August 2003) by Althouse, Turnquist, and Bracciano, Goodheart-Wilcox Publisher; 18th edition. International Mechanical Code (March 6, 2006) by the International Code Council, Thomson Delmar Learning; 1 edition. ASHRAE Handbook: Fundamentals, Atlanta, GA, 2009. http://creativecommons.org/licenses/by-sa/3.0/